Balanced Temperatures and Greater Comfort
Warm air naturally rises, creating temperature differences between the ceiling and floor. PureAir directs air downward to mix these layers, helping maintain more consistent temperatures throughout the occupied space.
Built-In PHI-Cell® Air Purification
PureAir integrates RGF’s PHI-Cell® technology into the fan assembly, combining continuous air circulation with air purification. The system helps reduce airborne viruses, bacteria, mold, and odors while enhancing destratification performance.
Lower HVAC Energy Use
By reducing ceiling-to-floor temperature differences, PureAir helps HVAC systems maintain comfortable conditions more efficiently. Destratification can reduce HVAC energy use by 20–35%, supporting energy efficiency and decarbonization initiatives.
Flexible Models and Installation
PureAir offers standard and short nozzle configurations to accommodate ceiling height. Models are available in off-white or black, with 120VAC and 277VAC options.
PureAir is designed for open-ceiling and high-bay spaces where temperature stratification, uneven comfort, and indoor air quality are concerns. Potential applications include:
| Model # | Input Power | Amps | Watts | RPM | dB(A)1 | Weight | PHI |
|---|---|---|---|---|---|---|---|
| PHI-15-STD-(X) | 120VAC, 60Hz | .26 | 28 | 1057 | 33, 27, 23 | 9 lbs. | 9 in. |
| PHI-15-SH-(X) | 120VAC, 60Hz | .26 | 27 | 1057 | 33, 27, 23 | 7 lbs. | 5 in. |
| PHI-25-STD-(X) | 120VAC, 60Hz | .39 | 47 | 1670 | 35, 33, 31 | 9 lbs. | 9 in. |
| PHI-25-STD-(X)-277 | 277VAC, 60Hz | .20 | 55 | 1650 | 35, 33, 31 | 9 lbs. | 9 in. |
| PHI-25-SH-(X) | 120VAC, 60Hz | .39 | 46 | 1670 | 35, 33, 31 | 7 lbs. | 5 in. |
| PHI-25-SH-(X)-277 | 277VAC, 60Hz | .20 | 54 | 1650 | 35, 33, 31 | 7 lbs. | 5 in. |
(1) Calculated sound pressure at 15,20 and 25 foot distances based on non-reflective area. 60 dB(A) Sound Power Level, designed to meet ISO 3744 – engineering grade precision for determining sound power. Data independently verified by third party. Tests performed in-unit.
| All Models | |
|---|---|
| Housing: | ABS, UL 94 5VA flame resistance. For increased chemical reistance to oils and alkalies. |
| Hardware: | Stainless steel for increased corrosion resistance. |
| Motor: | 228mm, single phase, shaded pole, axial motor. Motor is thermally protected. Operating temperature: -4˚ F (-20˚ C) to 158˚ F (70˚ C). No lubrication required. Bearings are sealed. |
| Power Cord: | 6 foot cord and plug provided for 120V fans. |
| Control Input: | Fixed speed. |
| Stator: | Multi-vane stator significantly increases air throw for maximizing performance. |
| PHI Cell: | 5 inch cell for short nozzle fans, 9 inch cell for standard nozzle fans |
| Safety Cable: | 6’ length steel cable (fastened to body) |
| Warranty: | 3 years parts and workmanship for fan 2 years parts and workmanship for PHI cell |